E2H

Updated on 21/11/2025

To complete the copy follow the procedure as indicated

  1. Start copying until you reach the "Check Operation" screen.
  2. Press the menu button at the top right to enter manual recording as shown in the image below
  3. Move the slider above 6 seconds

  4. On the Ditec control unit, locate the buttons and display, indicated in blue:

  5. Press the "ENTER" key to enter the menu, the display performs a diagnostic test with all segments lit, then shows "AT"
  6. Using the "UP" and "DOWN" keys navigate the menu until the display shows "R0"
  7. Press "ENTER"
  8. Using the "UP" and "DOWN" keys navigate the menu until the display shows "SR"
  9. Press "ENTER", the "SR" text starts flashing
  10. In the 1Control app, press the "Transmit opening signal" button
  11. Wait 10 seconds, during which the display should show "OK"
    If "OK" is not displayed, increase the transmission time and/or move the SOLO closer to the control unit and press the transmission button again.
  12. Press "ESC"
  13. Press and hold "ESC" until the display turns off

This guide in other languages: Italiano Deutsch Français